SMOK Package Components
SMOK Debug Components
|
|
| Name
| Register |
| Symbol
|  |
| Remarks
| A Register contains a value. It's output during the
ClockUp portion of each cycle is the last value written into the
register. On ClockDown, if the control line W is non-zero,
the value of the input line is latched into the internal storage of
the Register. |
| User-Settable Attributes
|
Name
Width - 1 to 32 bits
Current Value
Initial Value - This value is the one saved with the model, and will be
the initial value when the saved model is read. It is also the value
to which the register is set when a machine reset is performed. |
|